X13288

STC 3008 STC 3018 STC 3028 Dual Digital Temperature Humidity Controller Thermostat 10A With NTC Sensor Probe Thermoregulator

X13288

Sale price $14.99 Regular price $17.98

Tax included.
STC-3008 STC-3018 STC-3028 Dual Digital Temperature Humidity Controller Thermostat 10A With NTC Sensor Probe Thermoregulator

[STC-3008]


Description:
Switch the modes between cool and heat;
Control temperature by setting the temperature setting value and the difference value;
Temperature calibration;
Refrigerating control output delay protection;
Alarm when temperature exceeds temperature limit or when sensor error.

Specification:

Front panel size: 75x34.5(mm)

Mounting size: 71x29(mm)

Product size: 75x34.5x85(mm)

Sensor length: 1 meter (include the probe)


Technical Parameters:

Temperature measuring range: -55-120 Celsius

Accuracy: 0.1 Celsius

Sensor error delay: 1 minute

Power supply: DC 12V DC 24V AC 110-220V

Power consumption: <3w

Sensor: NTC sensor

Relay contact capacity: Cool (10A/240VAC); Heat (10A/240VAC)

Ambient temperature: 0-60 Celsius

Storage temperature: -30-75 Celsius

Relative humidity: 20-85%(No condensate)


Set start up temperature:


Press the "up" button once to display the starting temperature. Long press the "up" button for about 3 seconds,The required temperature can be set by the up and down keys


Set the stop temperature:


Press the button once to display the stop temperature. Long press the button for about 3 seconds and the stop temperature number flashes. The required temperature can be set by the up and down keys

[STC-3018]

 

Technical Parameters:

 

Temperature measuring range: -55 ° C ~ 120 ° C / -66°F~248°F

Accuracy: 0.1 Celsius

Sensor error delay: 1 minute

Power supply: DC 12V DC 24V AC 110-220V

Power consumption: <3w

Sensor: NTC 10K

Relay contact capacity: Cool (10A/240VAC); Heat (10A/240VAC)

Ambient temperature: 0-60 Celsius

Storage temperature: -30-75 Celsius

Relative humidity: 20-85%(No condensate)

Code Instruction:

 

Code

Function

Set Range

Default

 

Start or Stop Temperature

-55~120°C/-67~248°F

0°C/68°F

P0

Working mode

H

H/C

P1

Difference set value

0.2-10

2

P2

High temperature alarm value

-55~120°C/-67~248°F

80°C/176°F

P3

Low temperature alarm value

-55~120°C/-67~248°F

-55°C/-67°F

P4

Temperature calibration value

-10.0°C~10.0°C

0

P5

Compressor delay time

0-60Min

0

P6

Display mode

C/F

C

[STC-3028]


Technical Parameters:

Temperature measuring range: -20-80 Celsius
Measuring humidity range:00%RH~+100%RH
Accuracy: 0.1 Celsius
Power supply: DC 12V DC 24V AC 110-220V
Sensor: NTC sensor
Relay contact capacity: Cool (10A/240VAC); Heat (10A/240VAC)
Sensor length: 1 meter (include the probe)
Shell material:PC and ABS

 

X13289 (5)X13289 (14)X13289 (5)X13289 (3)X13289 (2)X13289 (6)X13289 (1)X13289 (4)

X13289 (17)X13289 (7)X13289 (16)X13289 (15)X13289 (8)X13289 (9)X13289 (11)X13289 (12)



HTB1Yr5IPxjaK1RjSZKzq6xVwXXa9HTB1Yr5IPxjaK1RjSZKzq6xVwXXa9
HTB1Yr5IPxjaK1RjSZKzq6xVwXXa9HTB1Yr5IPxjaK1RjSZKzq6xVwXXa9
HTB1Yr5IPxjaK1RjSZKzq6xVwXXa9

X13288 (3) X13289 (3) X13290 (3)